E-mail: service@1001718.com
DR5200
DR5200 - 2-Wire / 10GHz Radar (FMCW) Level MeterThis device is a non-contact radar level meter that uses FMCW technology. It measures distance, level and volume of liquids and pastes.
DR5200的詳細資料
DR5200
DR5200 - 2-Wire / 10GHz Radar (FMCW) Level Meter | ||
![]() |
This device is a non-contact radar level meter that uses FMCW technology. It measures distance, level and volume of liquids and pastes. It is ideal for measuring the level of corrosive products with its PP or PTFE antenna options. Features
|
Specifications | ||
![]() |
Measuring system | |
Measuring principle | 2-wire loop-powered level transmitter; X-band (10 GHz) FMCW radar |
Application range | Level measurement of liquids, pastes and slurries |
Primary measured value | Distance and reflection |
Secondary measured value | Level, volume, mass and flow rate |
Design | |
Construction | The measurement system consists of a measuring sensor (antenna) and a signal converter |
Options | Integrated LCD display (-20..+60°C/ -4…+140°F); if the ambient temperature is not in these limits, the display switches off automatically |
High-temperature (HT) extension (if the process connection temperature is more than +150°C / +302°F - Metallic Horn antenna only) | |
Straight antenna extensions | |
"S" antenna extension | |
"L" (right angle) antenna extension | |
Antenna purging system | |
Heating / cooling system (with or without the antenna purging system) | |
Signal cable for remote housing version (refer to cable properties in "Electrical connection: Remote device version") | |
Weather protection - for the compact version or the antenna housing (remote version). It cannot be ordered after delivery of the device. | |
Max. Measuring range | PTFE and PP Wave Horn antennas: |
DN80 / DN100 Metallic Horn antennas (installation only in stilling wells): | |
DN150 / DN200 Metallic Horn antennas: | |
Wave Guide antenna: | |
Also depends on the dielectric constant of the product and the installation type. Refer also to "Antenna selection". | |
Min. tank height | 1m/ 3.3 ft |
Top dead zone | Minimum value: Antenna length+antennna extension length+100mm / 3.9¨ |
Beam angle (½ angle) of antenna | PP Wave Horn: 10° |
PTFE Wave Horn: 10° | |
Metallic Horn DN80 / 3¨: 16° - used only in stilling wells | |
Metallic Horn DN100 / 4¨: 12° - used only in stilling wells | |
Metallic Horn DN150 / 6¨: 8° | |
Metallic Horn DN200 / 8¨: 6° | |
Wave Guide / stilling well: n/a - the radar signal is inside the tube. | |
Display and user interface | |
Display | LCD display |
Interface languages | 3 language pack options (the language is given in the customer order): |
Measuring accuracy |
|
Resolution | 1mm/ 0.04¨ |
Repeatability | ±1mm/ ±0.04¨ |
Accuracy | Standard: ±10mm / ±0.4¨, when distance < 10 m / 33 ft; ±0.1% of measured distance, when distance > 10 m / 33 ft |
Reference conditions acc. to EN 61298-1 | |
Temperature | +15...+25°C / +59...+77°F |
Pressure | 1013 mbara ±50 mbar / 14.69 psia ±0.73 psi |
Relative air humidity | 60% ±15% |
Target | Metal plate in an anechoic chamber |
Operating conditions |
|
Temperature | |
Ambient temperature | -40…+80°C/ -40…+176°F |
Storage temperature | -50…+85°C/ -58…+185°F |
PP Wave Horn antenna: | |
PTFE Wave Horn antenna: | |
Metallic Horn antenna / Wave Guide antenna: | |
Pressure | |
Process pressure | PP Wave Horn antenna: |
PTFE Wave Horn antenna: | |
Metallic Horn antenna / Wave Guide antenna: | |
Purging system (option) | Max. 6 barg / 87 psig (higher pressure on request) |
Heating / cooling system (option) | Max. 6 barg / 87 psig (higher pressure on request) |
Other conditions |
|
Dielectric constant (?r) | Direct mode: ≥1.8 |
Ingress protection | IEC 60529: IP 66/67 |
NEMA 250: NEMA type 4X (housing) and type 6P (antenna) | |
Maximum rate of change | 10 m/min / 32.8 ft/min |
Installation conditions |
|
Process connection size | The nominal diameter (DN) should be equal to or larger than the antenna diameter. |
Process connection position | Make sure that there are not any obstructions directly below the process connection for the device. For more data, refer to Installation on page 31. |
Dimensions and weights | For dimensions and weights data, refer to Dimensions and weights on page 24. |
Materials |
|
Housing | Standard: Polyester-coated aluminium |
Option: Stainless steel (1.4404 / 316L) | |
Antenna options / Wetted materials | PTFE Wave Horn antenna with a PTFE flange cladding |
PP Wave Horn antenna with a PP jacket/threaded process connection | |
Stainless steel (1.4404 / 316L) Metallic Horn antenna with a PTFE process seal and an FKM/FPM, EPDM, Kalrez® 6375 or PFA O-ring gasket | |
Stainless steel (1.4404 / 316L) Wave Guide antennas with a PTFE process seal and an FKM/FPM, EPDM, Kalrez® 6375 or PFA O-ring gasket | |
Feedthrough | PP Wave Horn antenna: this is a single-piece antenna (the feedthrough is filled with PP) |
PTFE Wave Horn antenna: this is a single-piece antenna (the feedthrough is filled with PTFE) | |
Metallic Horn and Wave Guide antennas: Dual process seal system | |
Cable gland | Standard: none |
Options: Plastic (Non-Ex: black, Ex i-approved: blue); nickel-plated brass; stainless steel | |
Weather protection (Option) | Stainless steel (1.4404 / 316L) |
Process connections |
|
Thread | PP Wave Horn antenna: G 1½; 1½ NPT |
Flange version | |
EN | PTFE Wave Horn antenna: DN50…150 in PN16, PN40 |
Metallic Horn and Wave Guide antennas: DN80…200 in PN16, PN40; others on request | |
ASME | PTFE Wave Horn antenna: 2¨…6¨ in 150 lb / 300 lb |
Metallic Horn and Wave Guide antennas: 3¨…8¨ in 150 lb / 300 lb; others on request | |
JIS | PTFE Wave Horn antenna: 50...150A in 10K |
Metallic Horn and Wave Guide antennas: 80…200A in 10K; others on request | |
Other | Others on request |
Electrical connections |
|
Power supply | Terminals output - Non-Ex / Ex i: |
Terminals output - Ex d: | |
Maximum current | 22mA |
Current output load | Non-Ex / Ex i: RL [Ω] ≤ ((Uext -12 V)/22mA). For more data, refer to Minimum power supply voltage on page 17. |
Ex d: RL [Ω] ≤ ((Uext -16 V)/22mA). For more data, refer to Minimum power supply voltage on page 17. | |
Cable entry | Standard: M20×1.5; Option: ½ NPT |
Cable gland | Standard: none |
Options: M20×1.5 (cable diameter: 6...10mm / 0.2...0.39¨); others are available on request | |
Cable entry capacity (terminal) | 0.5…2.5mm² |
Input and output |
|
Output signal | 4…20mA HART® or 3.8…20.5mA acc. to NAMUR NE 43 3 |
Resolution | ±3 µA |
Temperature drift | Typically 50 ppm/K |
Digital temperature drift | Max. ±15mm / 0.6¨ for the full temperature range |
Error signal | High: 22mA; Low: 3.6mA acc. to NAMUR NE 43 |
|
|
|
|
Approvals and certification | |
CE | This device fulfils the statutory requirements of the EC directives. The manufacturer certifies successful testing of the product by applying the CE mark. |
Vibration resistance | EN 60068-2-64 |
Metallic Horn (without antenna extension options): 5Hz to 100Hz: 4g |
|
Metallic Horn, PTFE or PP Wave Horn: 3.5mm up to 8Hz and 10 m/s²: 1g, |
|
8.5 to 2000Hz |
|
Explosion protection | |
ATEX | II 1/2 G, 2 G Ex ia IIC T6...T2 Ga/Gb or Ex ia IIC T6...T2 Gb; |
II 1/2 D, 2 D Ex ia IIIC T90°C Da/Db or Ex ia IIIC T90°C Db IP6X; | |
II 1/2 G, 2 G Ex d ia IIC T6...T2 Ga/Gb or Ex d ia IIC T6...T2 Gb; | |
II 1/2 D, 2 D Ex ia tb IIIC T90°C Da/Db or Ex ia tb IIIC T90°C Db IP6X | |
IECEx | Ex ia IIC T6…T2 Ga/Gb or Ex ia IIC T6…T2 Gb; |
Ex ia IIIC T90°C Da/Db or Ex ia IIIC T90°C Db IP6X; | |
Ex d ia IIC T6...T2 or Ex d ia IIC T6...T2 Gb; | |
Ex ia tb IIIC T90°C Da/Db or Ex ia tb IIIC T90°C IP6X | |
cFMus - Dual Seal-approved | NEC 500 |
XP-IS / Cl. I / Div. 1 / Gr. ABCD / T6; | |
DIP / Cl. II/III / Div. 1 / Gr. EFG / T6; | |
IS / Cl. I/II/III / Div. 1 / Gr. ABCDEFG / T6; | |
NI / Cl. I / Div. 2 / Gr. ABCD / T6 | |
NEC 505 | |
Cl. I / Zone 0 / AEx d [ia] / IIC / T6; | |
Cl. I / Zone 0 / AEx ia / IIC / T6; | |
Cl. I / Zone 2 / AEx nA [ia] / IIC / T6; | |
Hazardous (Classified) locationss, indoor/outdoor Type 4X and 6P, IP66, Dual Seal | |
CEC Section 18 (Zone ratings) | |
Cl. I, Zone 1, Ex d, IIC (Antenna: Zone 0), T6; | |
Cl. I, Zone 0, Ex ia, IIC, T6; | |
Cl. I, Zone 2, Ex nA, IIC, T6 DIP A21 IP66 TB 95°C | |
CEC Section 18 and Annex J (Division ratings) | |
Cl. I, Div. 1/2, Gr. ABCD; Cl. II, Gr. EFG; Cl. III, T6; | |
NEPSI (pending) | Ex ia IIC T2~T6 DIP A21 TA IP66; |
Ex d ia IIC T2~T6 DIP A21 TA IP66 | |
INMETRO (pending) | Ex ia IIC T6…T2 Ga/Gb |
Ex ia IIIC T90°C Da/Db IP6X | |
Ex d [ia Da] IIC T6…T2 Ga/Gb | |
Ex tb [ia Da] IIIC T90°C Db IP6X | |
Other standards and approvals | |
SIL | Compact version only: SIL 2 - according to EN 61508 and for high/low demand mode operation |
EMC | Electromagnetic Compatibility Directive 2004/108/EC in conjunction with EN 61326-1 (2006) |
|
|
|
|
Radio approvals | R & TTE |
FCC Rules | |
Industry Canada | |
LVD | Low-Voltage Directive 2006/95/EC in conjunction with EN 61010-1 (2001) |
NAMUR | NAMUR NE 21 Electromagnetic Compatibility (EMC) of Industrial Process and Laboratory Control Equipment |
| NAMUR NE 43 Standardization of the Signal Level for the Failure Information of Digital Transmitters |
| NAMUR NE 53 Software and Hardware of Field Devices and Signal Processing Devices with Digital Electronics |
| NAMUR NE 107 Self-Monitoring and Diagnosis of Field Devices |
CRN | This certification is applicable for all Canadian provinces and territories. For more data, refer to the website. |
Construction code | Metallic Horn and Wave Guide antennas: NACE MR0175 / ISO 15156; NACE MR0103 |
1 If the process connection temperature is more than 150°C/ 302°F and the device has Kalrez® 6375 or FKM/FPM gaskets, the device will also have an high temperature extension between the converter and the process connection. Kalrez® is a registered trademark of DuPont Performance Elastomers L.L.C.The process connection temperature must agree with the temperature limits of the gasket ma- terial. 2 Metaglas® is a registered trademark of Herberts Industrieglas, GMBH & Co., KG 3 HART® is a registered trademark of the HART Communication Foundation |
該產品由深圳市小黄鸭视频下载電子科技有限公司提供,銷售商地址位於深圳市南山區前海路振業國際商務中心1206。請您仔細閱讀產品使用說明書,正確使用。
如果想試用該產品,請本單位:
小黄鸭视频下载電子主要銷售通信設備、儀器儀表、電力設備、熱工儀表、校準設備及工具配件。有多功能多產品校準器、電能功率校準器、活塞式小黄鸭视频污APP(氣體、高壓、液體、真空)、多功能電氣安全校準器、示波器、頻率計、萬用表、阻抗小黄鸭黄色饮件、功率計、LCR數字電橋、音頻小黄鸭黄色饮件、電容測試儀、電感測試儀、安規測試儀、直流電阻測試儀、網絡小黄鸭黄色饮件、頻譜儀、任意波形發生器、溫度校準儀、數字測溫儀、信號發生器、電源、電子負載、綜合測試儀、信號源、濾波器測試儀、材料試驗機、溫度傳感器、熱像儀、變壓器測試儀、噪聲源、視頻小黄鸭黄色饮件、過程校準儀、溫度巡檢儀、超級測溫電橋、黑體爐、射頻導納物位開關、多點物位開關、音叉開關、射頻導納連續物位計、雷達液位計、超聲波液位計、油中水含量小黄鸭黄色饮件、液位測量係統、磁致伸縮液位計、非接觸固體雷達、壓力傳感器、過程表、壓力變送器、氣動控製器、高純壓力開關、隔膜片、衝液表、計量表膜片密封、材料實驗機、食品質構儀、硬度實驗機、數字測力計、PETPLUS特性粘度儀、布氏光學掃描係統、洛氏布硬度實驗機、全自動顯微硬度試驗機、布氏硬度試驗機、電動試驗平台、單柱材料試驗係統、雙柱材料試驗係統、浮球活塞小黄鸭视频污APP、船用溫度壓力校驗儀、點位測量係統、超聲波開關、油/水界麵開關、在線流體檢測開關、多點開關、平板開關、浮頂罐溢出保護開關、空氣加熱器、織物加熱套、電加熱帶、矽橡膠加熱毯、圓桶加熱器、IBC加熱器、氣體加熱器、灰鬥加熱係統、自限溫電伴熱帶、恒功率電伴熱帶、恒功率電伴熱帶、覆套式電阻加熱器、電阻絲、溫度控製器、危險環境加熱器及控製、複合材料修補儀、真空修補/處理平台、A320升降舵無損檢驗包;靜電放電幹擾模擬器、雷擊浪湧幹擾模擬器、周波跌落模擬器、輻射抗擾度係統、脈衝群幹擾模擬器、傳導抗擾度測試係統、傳導幹擾測試係統、輻射幹擾測試係統等儀器。
![]() |
||||
|
||||
![]() |